Switches come in two basic types: Momentary Action and Alternate Action
• A momentary switch changes state during activation and reverts to its original state upon deactivation. ie: Doorbell Switch
• A timer can be used with a momentary switch to activate the switch contacts for a specific amount of time
• An Alternate Switch changes state upon activation and does not change back until reactivated. ie: Light Switch
• Alternate switches are also called Maintained or Latching switches
A (NO) contact means that the circuit is open and the voltage is not
transferred through its normal state.
Wired in Parallel for Fail Secure type electric locks.
ie: Electric strike
Activating any switch will apply power releasing the lock.
A (NC) contact means that the circuit is closed and voltage is
transferred through its normal state.
Wired in Series for Fail Safe type electric locks.
ie: Securitron Magnalocks
Activating any switch will break power releasing the lock.
Essential Information
Switch Selection Guide
Double Pole - Single Throw
Double Pole - Double Throw
Single Pole - Single Throw
Switches that have one input and only one output
(NO or NC) are called Single Pole - Single Throw (SPST)
Single Pole - Double Throw
Switches with one input and two outputs are called
Single Pole - Double Throw (SPDT)
Switches with two inputs and only one output each
(NO or NC) are called Double Pole - Single Throw (DPST)
Switches with two inputs and two outputs each are
called Double Pole - Double Throw (DPDT)
Momentary vs Alternate
(NO) Normally Open Contacts (NC) Normally Closed Contacts